Hanna Multiparameter Waterproof Meter HI98194
Hanna Multiparameter Waterproof Meter HI98194 is backordered and will ship as soon as it is back in stock.
Couldn't load pickup availability
Description
Description
The Hanna HI98194 is a portable waterproof (IP67) logging multi-parameter meter measuring pH, ORP, conductivity, dissolved oxygen, and temperature via a single multi-sensor probe (IP68, quick-connect DIN). A backlit graphic LCD displays up to twelve parameters simultaneously with virtual-key navigation. Features auto-sensor recognition, field-replaceable colour-coded sensors, automatic temperature compensation, built-in barometer for DO pressure compensation, and up to 45,000 log-on-demand or continuous readings (1-second to 3-hour intervals). Standard or quick calibration available for each parameter. GLP calibration data accessible via dedicated key. Data transfer to PC via USB with HI9298194 software. Battery life up to 360 hours (4 × AA batteries). Supplied in a rugged thermoformed carrying case.
Science Essentials has supplied quality laboratory equipment and consumables to Australian laboratories since 1979. Brisbane-based with Australia-wide delivery.
Technical Information
Technical Information
| pH Range | 0. 00 to 14. 00 pH |
| pH Resolution | 0. 01 pH |
| pH Accuracy | ±0. 02 pH |
| pH Calibration | automatic one, two, or three points with automatic recognition of five standard buffers (pH 4. 01, 6. 86, 7. 01, 9. 18, 10. 01) or one custom buffer |
| mV Range | ±600. 0 mV |
| mV Resolution | 0. 1 mV |
| mV Accuracy | ±0. 5 mV |
| ORP Range | ±2000. 0 mV |
| ORP Resolution | 0. 1 mV |
| ORP Accuracy | ±1. 0 mV |
| ORP Calibration | automatic at one custom point (relative mV) |
| EC Range | 0 to 9999 S/cm; 0. 000 to 200. 0 mS/cm (absolute EC up to 400. 0 mS/cm) |
| EC Resolution | auto-ranging: 1 S/cm from 0 to 9999 S/cm; 0. 01 mS/cm from 10. 00 to 99. 99 mS/cm; 0. 1 mS/cm from 100. 0 to 400. 0 mS/cm; auto-ranging (fixed mS/cm): 0. 001 mS/cm from 0. 000 to 9. 999 mS/cm; 0. 01 from 100. 0 to 400. 0 mS/cm ; manual: 1 S/cm; 0. 001 mS/cm; 0. 01 |
| EC Accuracy | ±1% of reading or ±1 S/cm whichever is greater |
| EC Calibration | automatic single point, with six standard solutions (84 S/cm, 1413 S/cm, 5. 00 mS/cm, 12. 88 mS/cm, 80. 0 mS/cm, 111. 8 mS/cm) or custom point |
| TDS Range | 0 to 9999 ppm (mg/L); 0. 000 to 400. 0 ppt (g/L) (maximum value depends on TDS factor) |
| TDS Resolution | manual: 1 ppm (mg/L); 0. 001 ppt (g/L); 0. 01 ppt (g/L); 0. 1 ppt (g/L); 1 ppt (g/L); auto-ranging: 1 ppm (mg/L) from 0 to 9999 ppm (mg/L); 0. 01 ppt (g/L) from 10. 00 to 99. 99 ppt (g/L); 0. 1 ppt (g/L) from 100. 0 to 400. 0 ppt (g/L); auto-ranging (fixed ppt): |
| TDS Accuracy | ±1% of reading or ±1 ppm (mg/L), whichever is greater |
| TDS Calibration | based on conductivity calibration |
| Resistivity Range | 0 to 999999 O•cm; 0 to 1000. 0 kO•cm; 0 to 1. 0000 MO•cm |
| Resistivity Resolution | dependent on resistivity reading |
| Resistivity Calibration | based on conductivity calibration |
| Salinity Range | 0. 00 to 70. 00 PSU |
| Salinity Resolution | 0. 01 PSU |
| Salinity Accuracy | ±2% of reading or ±0. 01 PSU whichever is greater |
| Salinity Calibration | based on conductivity calibration |
| Seawater s Range | 0. 0 to 50. 0 st, s0, s15 |
| Seawater s Resolution | 0. 1 st, s0, s15 |
| Seawater s Accuracy | ±1 st, s0, s15 |
| DO Range | 0. 0 to 500. 0%; 0. 00 to 50. 00 ppm (mg/L) |
| DO Resolution | 0. 1%; 0. 01 ppm (mg/L) |
| DO Accuracy | 0. 0 to 300. 0% saturation: ±1. 5% of reading or ±1. 0% saturation whichever is greater, 0. 00 to 30. 00 ppm (mg/L): ±1. 5% of reading or ±0. 10 ppm (mg/L), whichever is greater, 30. 00 ppm (mg/L) to 50. 00 ppm (mg/L): ±3% of reading, 300. 0 to 500. 0% saturation: ±3% of reading |
| DO Calibration | automatic one or two points at 0 and 100% or one custom point |
| Atmospheric Pressure Range | 450 to 850 mm Hg; 17. 72 to 33. 46 in Hg; 600. 0 to 1133. 2 mbar; 8. 702 to 16. 436 psi; 0. 5921 to 1. 1184 atm; 60. 00 to 113. 32 kPa |
| Atmospheric Pressure Resolution | 0. 1 mm Hg; 0. 01 in Hg; 0. 1 mbar; 0. 001 psi; 0. 0001 atm; 0. 01 kPa |
| Atmospheric Pressure Accuracy | ±3 mm Hg within ±15°C from the temperature during calibration |
| Atmospheric Pressure Calibration | automatic at one custom point |
| Temperature Range | -5. 00 to 55. 00 °C, 23. 00 to 131. 00 °F, 268. 15 to 328. 15 K |
| Temperature Resolution | 0. 01 K, 0. 01 °C, 0. 01 °F |
| Temperature Accuracy | ±0. 15 °C; ±0. 27 °F; ±0. 15 K |
| Temperature Calibration | automatic at one custom point |
| Temperature Compensation | automatic from -5 to 55 °C (23 to 131 °F) |
| Logging Memory | 45,000 records (continuous logging or log-on-demand of all parameters) |
| Logging Interval | one second to three hours |
| PC Connectivity | USB to PC with HI9298194 Hanna software installed |
| Battery Type/Life | 1. 5V AA batteries (4) / approximately 360 hours of continuous use without backlight (50 hours with backlight) |
| Dimensions | 185 x 93 x 35. 2 mm (7. 3 x 3. 6 x 1. 4”) |
| Weight | 400 g (14. 2 oz. ) |
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.